久久久久久精品免费自在自线-色婷婷狠狠久久综合五月-国产成人香蕉久久久久-久久99精品久久久久久野外-国产成人久久精品二区三区,一级特黄AAA大片在线观看_国产一级a毛一级a看免费视频_久久午夜无码鲁丝片午夜精品_特级丰满少妇一级AAAA爱毛片_少妇一级婬片免费放一级a性色生活片久久无_亚洲国产成人精品女人久久久久国产一区二区三区 ,中文字幕在线观看,中文字幕在线播放,最新中文字幕在线,中文字幕第一页在线,最新中文字幕在线观看,在线播放中文字幕,日本中文字幕在线,中文字幕视频在线观看 ,91人妻人人澡人人爽人人精品_91精品婷婷国产综合久久_91成人无码免费一区二区尤物_国产一二中文字幕91影院日韩欧美_国产午夜无码喷水福利在线看91

Products

LungsReady Breathing Simulator

Model TYE6060
Product size(mm) 1530×755×540

Click here to watch video


Outline

The LungsReady Breathing Simulator creates an algorithm model based on the human body physiological and pathological characteristics of respiratory mechanics, and can simulate normal and different disease state of the human respiratory system by adjusting the mechanical parameters. It canbe used with real ventilators and anesthesia machines to trigger and respond as a real patient does, make it an ideal choice for ventilation management training in anesthesia, critical care, emergency medicine, respiratory care etc. It also finds wide applicationin respiratory disease research and real ventilator detection and calibration.


Intended Use

· Basic to advanced mechanical ventilation

· Simulate virtually any patient with respiratory conditions

· Respiratory disease research

· Development and testing for ventilators and other respiratory therapy devices


Features

·LungsReady workstation supports height adjustment from 0 to 40cm.

· 3L air storage capacity. By changing parameters, LungsReady is capable of simulating respiratory disease from the full range of patients – neonatal to adult, male to female with different weights.

·LungsReadyautomatically detects parameter adjustments and responds and reacts accordingly.

·LungsReadyuses high-precision bearings and ball screws to perform linear motion. Besides, a high-sensitivity encoder is applied for detection, which can precisely control the linear movement distance, thus accurately controlling the breathing air volume and achieving high-speed, smooth and noise-free operation.

·LungsReadycan detect the flow rate, pressure, tidal volume of the ventilator and anesthesia machine and generate corresponding waveforms (F-T, Paw-T, Pmus-T, Palv-T, V-T) and ring diagrams (F-V, Paw-V, Paw-F).

·When LungsReady simulates a patient without spontaneous breathing, controlled ventilation can be done by a ventilator. LungsReady can perform the corresponding breathing movement according to the mode and parameter settings of the mechanical ventilation.

·When LungsReady simulates a patient who has spontaneous breathing, the spontaneous breathing can trigger the mechanical ventilation. If the spontaneous breathing is strong, patient "fighting the ventilator" waveform will be generated. 

·The system comes with 15 real clinical cases and 50 basic respiratory mechanics models of healthy people and COPD, ARDS as well as other types of patients.Basic respiratory mechanics models can be expanded infinitely according to the needs of teachers.

·More than 20 common parameters such as compliance, airway resistance, respiratory muscle pressure, respiratory time ratio, respiratory frequency, functional residual capacity can be adjusted to affect the change of system breathing work. In addition to linear compliance, nonlinear compliance can also be adjusted.

·The changing trend of the patient's condition can be simulated through the trend breathing settings, such as simulating the gradual weakening of the respiratory muscle work after gas anesthesia; simulating the fluctuation of patient's breathing movement through random breathing to add more realism; simulating unstable breathing with diseases such as asthma.

·Quick buttons for common human symptoms and diseases such as coughing, sighing and suffocation can simulate the impact of coughing on ventilation, sigh-like breathing and waveform changes when suffocation occurs.

·LungsReady can monitor the real-time changes of 18 parameters such as respiratory rate, I:E ratio, and peak airway pressure with respiratory movement, and quickly set up the displayed monitoring parameters.

·LungsReady comes with built-in dynamic respiratory mechanics models, which can dynamically change with the performance of inhalation and exhalation. The range of tidal volumes can be set according to weight. There is corresponding indication for normal, insufficient, or excessive tidal volumes.

·The system supports operation review. Users can view operation log details, important parameter trends, and monitoring waveforms.Accounts can be created in the system and each user can see their own operation review, be it teaching or training.

·Running process can be stopped at any time and the waveforms can be frozen for comparative analysis.

·Instructors can adjust monitoring parameters, including heart rate and other values as well as dozens of common ECG waveforms.

·Learners can check the simulation monitoring interface and view the ECG waveforms of different leads on the learner's tablet display.

·Thesystem can generate a 12-lead ECG checklist for students to view.

·Instructors can edit no less than 50 kinds of laboratory tests such as blood gas analysis, chest X-ray, chest CT, lung functions, etc., and send them to learners for them to view through the learner's tablet display.

Tellyes, Virtually Real

Stock code :833047

Address:2nd & 3rd Floor, West 6th Building, 18 West HaiTai Road, Tianjin, China

Postcode:300384

Phone:4006-355-510

+86-22-83711066

Fax:+86-22-83711065

Email:info@tellyes.com

Tellyes Scientific INC.  Copyright  津ICP備14006255號(hào)-1
金华市| 南充市| 搜索| 诏安县| 通化县| 慈溪市| 平远县| 罗平县| 辽阳县| 寿阳县| 吴川市| 沂水县| 黎城县| 南川市| 兴义市| 开封市| 信丰县| 都江堰市| 富平县| 民乐县| 逊克县| 常德市| 淳安县| 临漳县| 永修县| 左贡县| 凤山县| 富源县| 揭东县| 云龙县| 汪清县| 华阴市| 平果县| 龙山县| 北票市| 区。| 巴林左旗| 眉山市| 民和| 贵德县| 八宿县|